DATA LIST / ACTIVE TEST
DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body / Main Body / Data List.
(e) According to the display on the Techstream, read the Data List.
Body Electrical > Main Body > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Mirror Selection SW (R) | Mirror select switch signal for RH mirror | ON/OFF | ON: Mirror select switch R switch on OFF: Mirror select switch R switch off | Only item displayed (not supported) |
Mirror Selection SW (L) | Mirror select switch signal for LH mirror | ON/OFF | ON: Mirror select switch L switch on OFF: Mirror select switch L switch off | Only item displayed (not supported) |
Mirror Position SW (R) | Mirror surface adjust switch signal (Right) | ON/OFF | ON: Mirror surface adjust switch pressed right OFF: Mirror surface adjust switch not pressed right | Only item displayed (not supported) |
Mirror Position SW (L) | Mirror surface adjust switch signal (Left) | ON/OFF | ON: Mirror surface adjust switch pressed left OFF: Mirror surface adjust switch not pressed left | Only item displayed (not supported) |
Mirror Position SW (Up) | Mirror surface adjust switch signal (Up) | ON/OFF | ON: Mirror surface adjust switch pressed up OFF: Mirror surface adjust switch not pressed up | Only item displayed (not supported) |
Mirror Position SW (Dwn) | Mirror surface adjust switch signal (Down) | ON/OFF | ON: Mirror surface adjust switch pressed down OFF: Mirror surface adjust switch not pressed down | Only item displayed (not supported) |
Outer Mirror Fold SW | Mirror retract switch signal | ON/OFF | ON: Mirror retract switch in retract position OFF: Mirror retract switch not in retract position | - |
Outer Mirror Return SW | Mirror retract switch signal | ON/OFF | ON: Mirror retract switch in return position OFF: Mirror retract switch not in return position | - |
ACTIVE TEST
HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / (desired system) / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test Tester Display | Measurement Item | Control Range | Diagnostic Note |
---|---|---|---|
Mirror Fold | Mirror retract operation | FOLD / OFF | - |
Mirror Return | Mirror retract operation | RETURN / OFF | - |
Tester Display | Measurement Item | Control Range | Diagnostic Note |
---|---|---|---|
Defogger Relay (Rear) | Mirror Heater | OFF/ON | w/ Mirror Heater |