Lexus NX: Data List / Active Test

DATA LIST / ACTIVE TEST

DATA LIST

HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the following table, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.

(e) Read the Data List according to the display on the Techstream.

Body Electrical > Air Conditioner > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

FR Seat Heater Temperature

Front seat RH heater temperature

-29.7°C to 59.55°C

Within range from 32 to 43°C (89 to 109°F)

Front seat heater is on

FL Seat Heater Temperature

Front seat LH heater temperature

-29.7°C to 59.55°C

Within range from 32 to 43°C (89 to 109°F)

Front seat heater is on

Number of Trouble Codes

Number of trouble codes

0 to 255

Number of DTCs will be displayed

-

READ NEXT:

 Diagnostic Trouble Code Chart

DIAGNOSTIC TROUBLE CODE CHART Seat Heater System DTC No. Detection Item Link B14C0 Front Right Seat Heat Sensor Circuit B14C1 Front Left Seat Heat Sensor Circuit B14C2

 Front Right Seat Heat Sensor Circuit (B14C0)

DESCRIPTION Output to the front seat cushion heater temperature sensor stops if one of the following occurs: 1) the temperature sensor is open or shorted; or 2) the temperature sensor is damaged and i

 Front Left Seat Heat Sensor Circuit (B14C1)

DESCRIPTION Output to the front seat cushion heater temperature sensor stops if one of the following occurs: 1) the temperature sensor is open or shorted; or 2) the temperature sensor is damaged and i

SEE MORE:

 Removal

REMOVAL CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH and LH sides. The procedure listed below is for the LH side. PROCEDURE 1. REMOVE BACK DOOR CENTER GARNISH Click here 2. REMOVE BACK DOOR SIDE GARNISH LH Click here 3. REMOVE BACK DOOR SIDE GARNISH RH Click here

 Removal

REMOVAL CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH and LH sides. The procedure listed below is for the LH side. PROCEDURE 1. PRECAUTION NOTICE: After the power switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery termi

© 2016-2024 Copyright www.lexunx.com