INSPECTION

PROCEDURE

1. INSPECT HEATER ACCESSORY ASSEMBLY

*a

Component without harness connected

(Heater Accessory Assembly (Heater Water Pump))

(a) Check the motor operation.

(1) Apply the positive (+) lead of the auxiliary battery to terminal 2 and the negative (-) lead to terminal 1.

OK:

Measurement Condition

Specified Condition

Auxiliary battery positive (+) → 2

Auxiliary battery negative (-) → 1

Heater accessory assembly operates smoothly

NOTICE:

Complete this inspection within 10 seconds if there is no water in the heater water pump assembly.

If the result is not as specified, replace the heater accessory assembly (heater water pump).

READ NEXT:

 Installation

INSTALLATION PROCEDURE 1. INSTALL HEATER ACCESSORY ASSEMBLY (a) Connect the heater water inlet hose A with the paint mark (Blue) facing up and attach the clip within the area shown in the illustrat

 Humidity Sensor

 Components

COMPONENTS ILLUSTRATION *1 AIR CONDITIONING THERMISTOR ASSEMBLY (HUMIDITY SENSOR) *2 NO. 1 FORWARD RECOGNITION COVER *3 NO. 2 FORWARD RECOGNITION COVER *4 PROTECTOR

SEE MORE:

 Components

COMPONENTS ILLUSTRATION *1 DECK FLOOR BOX LH *2 NO. 3 DECK BOARD SUB-ASSEMBLY *3 REAR DECK FLOOR BOX *4 NEGATIVE AUXILIARY BATTERY TERMINAL N*m (kgf*cm, ft.*lbf): Specified torque - - ILLUSTRATION *A for 8 Speakers *B for 10 Speakers *C for 14 Speake

 Invalid Data Received from HVAC Control Module (U0424-537)

DESCRIPTION If there is a malfunction in the air conditioning amplifier assembly, DTC U0424-537 will be stored. DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate U0424-537 Invalid Data Received from HVAC Control Module Air conditioning amplifier as

© 2016-2025 Copyright www.lexunx.com