1. INSPECT QUICK HEATER ASSEMBLY

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A-1 (B) - B-1 (E)

Always

Below 1 Ω

A-2 (E) - B-2 (B)

Always

Below 1 Ω

A-3 (B) - B-1 (E)

Always

Below 1 Ω

A-3 (B) - B-2 (B)

Always

Below 1 Ω

  • If the result is not as specified, replace the quick heater assembly.