DESCRIPTION
The curtain shield squib RH circuit consists of the airbag ECU assembly and curtain shield airbag assembly RH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH circuit.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
---|---|---|---|
B1830 | Short in Curtain Shield Airbag (RH) Squib Circuit | One of the following conditions is met:
|
|
B1831 | Open in Curtain Shield Airbag (RH) Squib Circuit | One of the following conditions is met:
|
|
B1832 | Short in Curtain Shield Airbag (RH) Squib Circuit (to Ground) | One of the following conditions is met:
|
|
B1833 | Short in Curtain Shield Airbag (RH) Squib Circuit (to +B) | One of the following conditions is met:
|
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
Click here
Click here
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
Click here
HINT:
To perform the simulation method, enter check mode (signal check) with the Techstream (Click here ), and then wiggle each connector of the airbag system or drive the vehicle on various types of road (Click here ).
PROCEDURE
1. | CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH |
(a) Turn the power switch off. |
|
(b) Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
(c) Disconnect the connector from the curtain shield airbag assembly RH.
(d) Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
CAUTION:
Never connect the tester to the curtain shield airbag assembly RH for measurement, as this may lead to a serious injury due to airbag deployment.
NOTICE:
SST: 09843-18061
(e) Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
(f) Turn the power switch on (IG), and wait for at least 60 seconds.
(g) Clear the DTCs.
Click here
Body Electrical > SRS Airbag > Clear DTCs(h) Turn the power switch off.
(i) Turn the power switch on (IG), and wait for at least 60 seconds.
(j) Check for DTCs.
Click here
Body Electrical > SRS Airbag > Trouble CodesHINT:
Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.
(k) Turn the power switch off.
(l) Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
(m) Disconnect SST from connector C.
DTC B1830, B1831, B1832 or B1833 is not output | REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH |
|
2. | CHECK CONNECTORS |
(a) Disconnect the connectors from the airbag ECU assembly.
(b) Check that the connectors (on the airbag ECU assembly side and curtain shield airbag assembly RH side) are not damaged. OK: The lock button is not disengaged, and the claw of the lock is not deformed or damaged. |
|
NG | REPLACE FLOOR WIRE |
|
3. | CHECK FLOOR WIRE |
(a) Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds. |
|
(b) Turn the power switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection | Switch Condition | Specified Condition |
---|---|---|
P10-1 (ICR+) - Body ground | Power switch on (IG) | Below 1 V |
P10-2 (ICR-) - Body ground | Power switch on (IG) | Below 1 V |
(d) Turn the power switch off.
(e) Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
(f) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
---|---|---|
P10-1 (ICR+) - P10-2 (ICR-) | Always | Below 1 Ω |
(g) Release the activation prevention mechanism built into connector B.
Click here
(h) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
---|---|---|
P10-1 (ICR+) - P10-2 (ICR-) | Always | 1 MΩ or higher |
(i) Restore the released activation prevention mechanism of connector B to its original condition.
(j) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
---|---|---|
P10-1 (ICR+) - Body ground | Always | 1 MΩ or higher |
P10-2 (ICR-) - Body ground | Always | 1 MΩ or higher |
NG | REPLACE FLOOR WIRE |
|
4. | CHECK DTC |
(a) Connect the connectors to the curtain shield airbag assembly RH and airbag ECU assembly. |
|
(b) Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
(c) Turn the power switch on (IG), and wait for at least 60 seconds.
(d) Clear the DTCs.
Click here
Body Electrical > SRS Airbag > Clear DTCs(e) Turn the power switch off.
(f) Turn the power switch on (IG), and wait for at least 60 seconds.
(g) Check for DTCs.
Click here
Body Electrical > SRS Airbag > Trouble CodesHINT:
Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.
DTC B1830, B1831, B1832 or B1833 is not output | USE SIMULATION METHOD TO CHECK |
DTC B1830, B1831, B1832 or B1833 is output | REPLACE AIRBAG ECU ASSEMBLY |